Home / Products / Syringe Filter

Syringe Filters Custom

Welch Materials, Inc.

Welch Materials, Inc. is a professional China Syringe Filters Manufacturers and Syringe Filters Factory in china, It's was established in August 2003 with its headquarter are currently located in Songjiang, Shanghai. It also has production and R&D facilities in Jinhua, Zhejiang and Nanjing, Jiangsu. We also have set subsidiaries in the United States, India and Canada. We are multinational company that develops and manufactures laboratory products including Syringe Filters, SPE cartridges, HPLC Column.Welch Materials, Inc. has integrated research, production, sales, and service, dedicated to become a one-stop laboratory suppliers in the world. Its products are widely used in industries such as biomedicine, food safety testing, environmental monitoring, and fine chemicals, which are essential to people's livelihood. By implementing rigorous quality inspection processes and adhering to strict standards, the company ensures that every product produced is compliant, meeting the highest laboratory requirements.
BRANDSTORY
About Us
Consumables Lab Biological

System
Certification

International system certification, effectively consolidate the competitiveness of the enterprise.

Contcat Us For A Quote Now.

For any inquiries from the customers,we will reply with the most professional and most reasonable price in time.

NEWS

*Industry Knowledge Development*
A syringe filter is a disposable filter device used to remove impurities and particles from liquids or gases. It consists of a plastic housing with a membrane filter at one end and a connector at the other end that allows attachment to a syringe. Syringe filters are commonly used in laboratories, pharmaceutical manufacturing, research, and other applications where sterile filtration is required.

The membrane filter in a syringe filter is typically made of materials such as cellulose acetate, polyethersulfone (PES), polypropylene, nylon, or polytetrafluoroethylene (PTFE). The choice of membrane material depends on the specific application and the nature of the substances being filtered.

Syringe filters come in various pore sizes, which determine the size of particles that can be retained by the filter. The pore size is usually specified in micrometers (μm) and can range from 0.1 μm to 5 μm or larger. Smaller pore sizes are used for fine filtration, such as removing bacteria or particles from liquid samples, while larger pore sizes are suitable for general filtration purposes.

To use a syringe filter, you attach it to the end of a syringe using the connector. The liquid or gas to be filtered is drawn into the syringe, and then it is pushed through the filter by applying gentle pressure on the syringe plunger. The filter retains the impurities and allows the filtered solution to pass through, providing a clean and purified sample.

Syringe filters are designed for single-use only and should be discarded after use. They are available in different sizes to accommodate various syringe volumes, ranging from a few milliliters to larger volumes.

It's important to note that while syringe filters can effectively remove particulates and microorganisms, they are not designed to sterilize solutions. If sterility is required, additional methods such as autoclaving or using sterile filtration systems should be employed.

Here's a step-by-step guide on how to use a syringe filter:
1.Gather the necessary materials: You will need the syringe filter, a syringe, the liquid you want to filter, and any additional equipment required for your specific application.
2.Prepare the syringe: Ensure that the syringe is clean and sterile before use. If it is not pre-sterilized, you may need to sterilize it by autoclaving or other appropriate methods.
3.Attach the syringe filter: Remove the protective cap from the syringe filter and screw it onto the end of the syringe tightly. Ensure a secure connection to prevent any leakage.
4.Prepare the liquid: If the liquid you want to filter contains particulate matter or impurities, it is recommended to pre-filter it using a larger-pore filter or by centrifuging it to remove any solid particles. This step is especially important if you are using a syringe filter with a smaller pore size.
5.Load the syringe: Draw the liquid you want to filter into the syringe. Make sure not to exceed the maximum capacity of the syringe, as this can cause leakage or damage to the filter.
6.Expel air bubbles: Hold the syringe upright and gently tap it to dislodge any air bubbles that may be trapped in the liquid. Then, slowly push the plunger to expel the air through the filter. This step ensures that only the liquid passes through the filter.
7.Begin filtration: Choose an appropriate collection vessel to receive the filtered liquid. Position the syringe vertically with the filter facing downwards. Apply gentle pressure to the plunger to initiate the filtration process.
8.Collect the filtrate: Allow the liquid to pass through the filter membrane and into the collection vessel. You can exert gentle pressure on the syringe plunger to facilitate the filtration process, but avoid applying excessive force, as it may rupture the filter or cause backflow.
9.Dispose of the syringe filter: Once filtration is complete, carefully detach the syringe filter from the syringe. Dispose of the used filter properly according to your laboratory's waste management guidelines.